Generator Guidelines

Generator Guidelines
Taking it to the Wall!

Technical Guide · Generators & Power Quality

Dirty Power from GeneratorsProtect your WerkMaster floor grinder

Portable and tow-behind generators are essential on job sites without access to utility power. However, an undersized generator or unstable power supply can cause VFD faults, equipment downtime, and costly repairs.

Understanding dirty power and choosing the right generator can help protect your WerkMaster grinder and keep your crew productive.

What Is Dirty Power?

Dirty power is electricity characterized by unstable voltage, fluctuating frequency, voltage spikes, or excessive Total Harmonic Distortion (THD).

WerkMaster grinders use Variable Frequency Drives (VFDs) to control motor speed and torque. Unlike basic power tools, these electronic systems are sensitive to poor power quality.

Feature Clean Power Dirty Power
Waveform Smooth, consistent sine wave Distorted or irregular
THD Typically below 3–5% May reach 10–30% or higher
Voltage Stable within specifications Fluctuates under load
Impact Reliable operation Faults, overheating, or premature failure

How Dirty Power Affects Your Grinder

Voltage Spikes

Sudden load changes, such as a dust collector cycling, can trigger VFD overvoltage (OV) faults and stop the machine.

Voltage Drops

When a generator struggles to maintain voltage under load, the VFD may draw more input current to maintain output power, increasing heat and stressing electronic components.

Harmonic Distortion

High THD can increase electrical losses, cause nuisance trips, and contribute to overheating in drive components and motor windings.

Common Causes

Undersized Generators

Insufficient capacity leaves little reserve for changing loads and startup demands.

Poor Regulation

Generators that cannot maintain stable voltage and frequency as loads change may cause equipment faults.

Unbalanced Phase Loads

Running 120V accessories from one leg of a three-phase generator can create phase imbalance.

Long or Undersized Extension Cords

Excessive cable length or insufficient wire gauge causes voltage drops. Heavier-gauge cable may be necessary, depending on the distance and load.

How to Protect Your Equipment

Follow these four steps to reduce power-related faults, prevent downtime, and protect your WerkMaster grinder.

01

Choose the Right Generator

Single-phase grinders10–12 kWas a general starting point
Three-phase commercial grinders25–45+ kVAdepending on motor horsepower and additional equipment

A generator rated at 2–2.5 times the continuous power draw may provide useful reserve capacity, but requirements vary. Confirm sizing with WerkMaster and your generator supplier.

02

Verify Power Quality

Choose a commercial-grade generator with effective Automatic Voltage Regulation (AVR) and good frequency control. Where required by your equipment, look for THD below 5% and confirm compatibility with your grinder’s voltage, phase, and frequency requirements.

03

Consider Additional Protection

A line reactor or isolation transformer may help address certain electrical disturbances, but neither corrects every power-quality problem. Consult a qualified electrician or equipment supplier before installation.

04

Follow Proper Startup and Shutdown Procedures

  • Allow the generator’s voltage and frequency to stabilize before powering on your grinder.
  • Turn off and disconnect the grinder according to the manufacturer’s instructions before shutting down the generator.

Keep Your Crew Grinding

Proper generator sizing, stable power, suitable cabling, and correct operating procedures can help reduce faults, prevent downtime, and protect your investment.

Download PDFGenerator Guidelines · PDF, 5 pages